STARTING PRICE/AS PER SPECS

SIZE: 12 X 3.6 X 2.44M
TECHNICAL SPECIFICATIONS WITH LIGHT GAUGE STEEL FRAMING SYSTEMFIRE RATED AS PER NFPA-5000

 


             

BASE FRAME   

The steel base frame shall be constructed from IPE  100/120 AA MS I Beam, full perimeter beams with central runner and cross members.   Spacing of transverse members=2500 mm c/c Spacing of longitudinal members=2000 mm c/c 

Lifting eyes are provided at intermediate points along with the perimeter beams. The Base frame shall painted with 02 coat paint, one with red oxide, one with rust free enamel paint.      

 

FLOOR 

Floor Frame: The Floor frame shall be constructed from MS angle 50x50x4mm welded into the base frame, making the floor assembly one integral frame.(600mm joists spacing). The floor frame shall be grit blasted to SA2.5 and painted with 02 coat system of epoxy paint. 

Floor decking: One layer of 18 mm thick cement board, fixed to the base frame and floor frame. Bottom of the cement board is painted with bitumen paint 

Floor finish in dry areas: High quality PVC sheet 1.5 mm fixed to 18mm thick cement board floor. 75 x 12mm thick pvc skirting.

Floor finish in toilet & pantry: As above.      

 

WALLS 

External Finish:  Fire rated 06 mm thick cement board finished with weather proof heavy texture paint. 

Internal Finish: Fire rated 12.5mm thick gypsum board finished with super white emulsion by Berger. 

Internal Finish in Toilet cabin: 6mm thick cement fibre board finished with white enamel paint, partition walls are of HPL sheet 12mm thick.

Wall Framing: LGS profile framing GI studs 70 x 35 x .5mm fixed together by screws at spacing of 610 mm vertically & 1200mm horizontally. Wall section is supported by Integral steel frame constructed with MS Tube 40x40x3mm welded with the base frame and trusses to provide durability in wall section.   

Internal Finish in Dry : 

Fire rated 12.5mm thick gypsum board having matt enamel painted in rooms & corridor without any visible joints on the walls. 

Wet areas: 6mm thick cement board finished with oil paint. 

Wall Insulation: 50mm thick Glass-wool insulation12kg/m3 density.     

Roof: Trusses are constructed by MS Angle 40x40x3mm with flat roof having the purlins of 40x40x3mm Ms angle.   Roof covering is 0.4mm thick corrugated powder coated gi sheet sides curved as per photo attached.  

 

CEILING   

False ceiling is fire rated 12.5 mm thick gypsum board painted white emulsion. Fixed on GI furring channels fixed at 610 mm C/c. Wall height will be 2440mm. Clear height (floor to false ceiling) is 2360 mm.       

 

DOORS   

External doors are 60 minutes fire rated powder coated steel sandwich type / aluminum  full frame doors with Iseo lock, door closer & complete ironmongery.

Internal doors : Semi solid wood doors / Wpvc doors size 800x2100mm. 

Toilet & pantry doors: Semi solid wood / Wpvc doors size 700x2100mm.  Door closer is to be provided only with the external main entrance doors. Door stopper: Half round floor door stopper shall be provided for all the doors.                

 

WINDOWS  

 Powder coated Aluminium frame white color windows with insect screen sliding type only 6 mm thick  glass without blinds size 900 x 900mm.      7.b 400 x 400mm powder coated aluminium windows are placed for the exhaust fans and ventilation.         

 

ELECTRICAL   

Electrical supply: Single phase 220 volts as per requirement with D/B Panel. Make – MEM / Hager/ ABB or equivalent. DBs are manufacture as per ADEWA standards. Elcb incomer & MCB out comer.  All wires are through PVC conduits concealed within walls. Pvc conduits for Tel & data sockets are provided with cover plates only.  8.b 2x36w fluorescent batten type fitting – Wet Areas (Make –Selex/Frater/Eqv), pictures attached. 2x18watt water proof IP65 lights in toilet & pantry. 13 amps and 15 amps switch socket outlets are – Legrand Brand / Tenby / equivalent. Wires origin is – Ducab / National / equivalent. Tel & data facets are provided with 25mm pvc conduits without cables.       

 

PLUMBING   

Piping: Water pipes shall be PPR for cold and hot water. Drainage pipes will be UPVC pipes. Sanitary-wares: Wash hand Basins will be pedestal type. EWC with cistern & seat cove by Home décor or Equiv. Shower tray with shower mixer is provided. All sanitary wares are standard white color and will be of Home décor or Equiv brand. Model as per approval by the client.       Looking mirror, Glass / plastic mirror shelf, SS soap tray, SS towel rod, SS coat hook is provided.

 

PANTRY 10 

Supply & installation of kitchen counter made with laminated ply wood finished with granite top, supply of SS sink with mixer.  

 

A/C UNITS   11  

Ms angle support will be provided for window A/c units and Isolator will be provided for Spilt A/c units. However the supply of A/c unit is excluded from our scope of work. Isolator will be provided for Spilt A/c units.